N9091EM0E Measuring Receiver Measurement Application


Release Date |
September 2024 |
S/W Version Date |
2024.0801 |
Operating System |
Microsoft Windows 10 |
Installer File Name |
XSA_Installer_A.39.29_Win10.exe |
Note: A.37.00 and above will only support multi-touch GUI X-apps programs inside the installer for bench-top X-Series analyzers. Traditional GUI X-apps are not included, and software licenses of traditional GUI X-apps are not recognized.
Note: This release does not support the Windows 7 operating system.

-
Fixed issue that caused “PM Zero Required” and “PM Cal Required” messages to appear after recalling a state (XSA-47040)


Release Date |
March 2024 |
S/W Version Date |
2024.0301 |
Operating System |
Microsoft Windows 10 |
Installer File Name |
XSA_Installer_A.38.01_Win10.exe |
Note: A.37.00 and above will only support multi-touch GUI X-apps programs inside the installer for bench-top X-Series analyzers. Traditional GUI X-apps are not included, and software licenses of traditional GUI X-apps are not recognized.
Note: This release does not support the Windows 7 operating system.

-
Force turn-off of RF Calibrator when in RF Power and Tuned RF Level (TRFL) measurements (XSA-40541)
-
Added on-screen indication when a power-meter zero and calibrate has completed successfully (XSA-40542)


Release Date |
January 2024 |
S/W Version Date |
2023.1201 |
Operating System |
Microsoft Windows 10 |
Installer File Name |
XSA_Installer_A.37.02_Win10.exe |
Note: A.37.00 and above will only support multi-touch GUI X-apps programs inside the installer for bench-top X-Series analyzers. Traditional GUI X-apps are not included, and software licenses of traditional GUI X-apps are not recognized.
NOTE: This release does not support the Windows 7 operating system.

-
Added support for N1913B and N1914B Power Meters

-
Increased default timeout for Power Meter from 15s to 30s to accommodate longer time necessary for doing zero and cal (XSA-37782)


Release Date |
August 2023 |
S/W Version Date |
2023.0801 |
Operating System |
Microsoft Windows 10 |
Installer File Name |
XSA_Installer_A.36.04_Win10.exe |
NOTE: This release contains a defect related to Noise Floor Extension (NFE) that is fixed with A.36.07
NOTE: This release does not support the Windows 7 operating system.

-
Fixed issue that caused modulation measurement ratio reference value to not be updated in result window when user keys in manual reference value (XSA-35838)


Release Date |
July 2022 |
S/W Version Date |
2022.0801 |
Operating System |
Microsoft Windows 10 |
Installer File Name |
XSA_Installer_A.33.03_Win10.exe |
NOTE: This release does not support the Windows 7 operating system.
NOTE: This release includes support of the N9067C and N9067EM0E Pulse measurement application

-
Add Vpp and Vp readout in Audio Level Measurement
-
Support Option FBP (Full Bypass) for Modulation measurements


Release Date |
July 2021 |
S/W Version Date |
2021.0701 |
Operating System |
Microsoft Windows 10 |
Installer File Name |
XSA_Installer_A.30.05.exe |
NOTE: This release does not support the Windows 7 operating system.

-
Added manual settings for low-pass and high-pass filters


Release Date |
June 2021 |
S/W Version Date |
2021.0201 |
Operating System |
Microsoft Windows 10 |
Installer File Name |
XSA_Installer_A.29.04.exe |
NOTE: This release does not support the Windows 7 operating system.

-
Added THD (Total Harmonic Distortion) for modulation

-
Fixed issue that caused a “Cannot start Connection Expert” exception to occur (XSA-14881)


Release Date |
December 2020 |
S/W Version Date |
2020.1101 |
Operating System |
Microsoft Windows 10 |
Installer File Name |
XSA_Installer_A.28.05.exe |
NOTE: This release does not support the Windows 7 operating system.

-
Fixed issue that resulted in the Go to Row feature not working when editing the Cal Factors table (XSA-10689)
-
Fixed issue that resulted in measurement application crashing after connecting U5532C power sensor (XSA-11097)
-
Fixed issue in Audio Frequency measurement that caused empty message box to be displayed when selecting a grayed-out 300 kHz Low Pass Filter (XSA-10493)
-
Fixed issue in Tuned RF Level measurement that caused the Reference unit to be displayed with a question mark (?) (XSA-10681)
-
Fixed issue that resulted in Cal Factor files not being loaded properly when the calibration date in the file was stored in the DD/MM/YYYY format; the default format of MM/DD/YYYY is OK. (XSA-9646)
-
Fixed issue that caused XSA application to crash with “VISA Exception” when a USB power sensor with old, incompatible firmware installed (XSA-9595)


Release Date |
July 2020 |
S/W Version Date |
2020.0701 |
Operating System |
Microsoft Windows 10 |
Installer File Name |
XSA_Installer_A.27.02.exe |
NOTE: This release does not support the Windows 7 operating system.

-
Added support for new USB Sensor On-Board Storage (with new sensor firmware)


Release Date |
March 2020 |
S/W Version Date |
2020.0220 |
Operating System |
Microsoft Windows 10 |
Installer File Name |
XSA_Installer_A.26.07.exe |
NOTE: This release does not support the Windows 7 operating system.

-
Fixed issue that caused USB power meter or power sensor to not respond or cause a connection timeout (XSA-923)


Release Date |
December 2019 |
S/W Version Date |
2019.1107 |
Operating System |
Microsoft Windows 7 or Microsoft Windows 10 |
Installer File Name |
XSA_Installer_A.25.05.exe |

-
Fixed issue in RF Power measurement where Channel B of the N1914A power meter could not be used to apply calibration data, or zero or cal the sensor module (528623)


Release Date |
August 2019 |
S/W Version Date |
2019.0702 |
Operating System |
Microsoft Windows 7 or Microsoft Windows 10 |
Installer File Name |
XSA_Installer_A.24.56.exe |

-
Added scroll bar for Measurements in Mode/Measurement screen (522594)
-
Fixed issue in Tuned RF Level measurement that caused Cal Factor 1 to not be cleared when changing frequency (522643)
-
Fixed error message for cases when Power Meter or sensor zero and calibration is needed to make message more obvious to user (522596)


Release Date |
April 2019 |
S/W Version Date |
2019.0228 |
Operating System |
Microsoft Windows 7 or Microsoft Windows 10 |
Installer File Name |
XSA_Installer_A.23.07.exe |

-
Fixed issue in RF Power measurement which caused an amplitude error when measuring RF power below 10 MHz unless User Power Meter/Sensor was toggled to No and then back to Yes (511259)


Release Date |
December 2018 |
S/W Version Date |
2018.1018 |
Operating System |
Microsoft Windows 7 or Microsoft Windows 10 |
Installer File Name |
XSA_Installer_A.22.08.exe |

-
Changed the default path for cal factor files to be non-measurement-specific, thus allowing sharing among measurements

-
Added several SCPI commands for backward compatibility to PSA (502529)
-
Improved messaging regarding power meter connection timeout when using U5532C at low power levels (503346)
-
Fixed issue with Frequency Counter measurement where Manual Frequency Tuning was not working properly for frequencies >= 13.5 GHz (507177)
-
Fixed issue in Tuned RF Level measurement that causes a debug assert warning to appear when recalling cal factors (508540)


Release Date |
July 2018 |
S/W Version Date |
2018.0629 |
Operating System |
Microsoft Windows 7 or Microsoft Windows 10 |
Installer File Name |
XSA_Installer_A.21.04.exe |

-
Added support for U5532C USB sensor module connectivity

-
Added SYSTem:COMMunicate:PMETer:TCONnect:STATe command to N9091EM0E Measuring Receiver application for backward compatibility to PSA (500864)


Release Date |
February 2018 |
S/W Version Date |
2017.1221 |
Operating System |
Microsoft Windows 7 |
Installer File Name |
XSA_Installer_A.20.03.exe |
WARNING:
Instrument software versions A.20.03 and A.20.04 have been found to contain a critical defect which may impact measurement accuracy. Do Not Upgrade to either of these versions.
If you recently upgraded to either A.20.03 or A.20.04, upgrade to A.20.22 or later

-
NEW - Only supported on N9030B as part of MMR-X (N5531X) system bundle